Added more specific default calibration values
This commit is contained in:
parent
ab07acd60c
commit
44c3e390b3
@ -153,10 +153,13 @@ class CalSetting:
|
|||||||
qty: Qty
|
qty: Qty
|
||||||
|
|
||||||
class CalibrationSettings:
|
class CalibrationSettings:
|
||||||
one = CalSetting('94 dB SPL', 94.0 , 1.0, SIQtys.AP)
|
one = CalSetting('94 dB SPL', 94.0 , 10**(94/20)*2e-5, SIQtys.AP.value)
|
||||||
two = CalSetting('114 dB SPL', 114.0 , 10.0, SIQtys.AP)
|
two = CalSetting('1 Pa rms', 93.98, 1.0, SIQtys.AP.value)
|
||||||
|
three = CalSetting('114 dB SPL', 114.0 , 10**(114/20)*2e-5, SIQtys.AP.value)
|
||||||
|
four = CalSetting('10 Pa rms', 113.98, 10.0, SIQtys.AP.value)
|
||||||
|
five = CalSetting('93.7 dB SPL', 93.7 , 1.0, SIQtys.AP.value)
|
||||||
|
|
||||||
types = (one, two)
|
types = (one, two, three, four, five)
|
||||||
default = one
|
default = one
|
||||||
default_index = 0
|
default_index = 0
|
||||||
|
|
||||||
|