Fixed #90, and set default sample rate back to 48k
This commit is contained in:
parent
b3476ba62f
commit
60afface35
@ -87,7 +87,9 @@ public:
|
||||
|
||||
if (handle == 0) {
|
||||
throw runtime_error("Unable to create a handle to the specified DAQ "
|
||||
"device. Is the device currently in use?");
|
||||
"device. Is the device currently in use? Please make sure to set "
|
||||
"the DAQ configuration in duplex mode if simultaneous input and "
|
||||
"output is required.");
|
||||
}
|
||||
|
||||
err = ulConnectDaqDevice(handle);
|
||||
@ -579,14 +581,14 @@ void fillUlDaqDeviceInfo(vector<DeviceInfo> &devinfolist) {
|
||||
devinfo.availableSampleRates.push_back(50400);
|
||||
devinfo.availableSampleRates.push_back(51000);
|
||||
|
||||
devinfo.prefSampleRateIndex = 5;
|
||||
devinfo.prefSampleRateIndex = 11;
|
||||
|
||||
devinfo.availableFramesPerBlock.push_back(512);
|
||||
devinfo.availableFramesPerBlock.push_back(1024);
|
||||
devinfo.availableFramesPerBlock.push_back(2048);
|
||||
devinfo.availableFramesPerBlock.push_back(4096);
|
||||
devinfo.availableFramesPerBlock.push_back(8192);
|
||||
devinfo.prefFramesPerBlockIndex = 1;
|
||||
devinfo.prefFramesPerBlockIndex = 2;
|
||||
|
||||
devinfo.availableInputRanges = {1.0, 10.0};
|
||||
devinfo.prefInputRangeIndex = 0;
|
||||
|